#!/bin/bash # Enable strict bash mode to stop the script if an uninitialized variable is used, if a command fails, or if a command with a pipe fails # Not working in some setups : https://github.com/tigerblue77/Dell_iDRAC_fan_controller/issues/48 # set -euo pipefail source functions.sh # Trap the signals for container exit and run gracefull_exit function trap 'gracefull_exit' SIGQUIT SIGKILL SIGTERM # Prepare, format and define initial variables # readonly DELL_FRESH_AIR_COMPLIANCE=45 # Define the temperature thresholds and corresponding fan speeds TEMP_THRESHOLDS=($CPU_TEMPERATURE_1 $CPU_TEMPERATURE_2 $CPU_TEMPERATURE_3 $CPU_TEMPERATURE_4) FAN_SPEEDS=($FAN_SPEED_1 $FAN_SPEED_2 $FAN_SPEED_3 $FAN_SPEED_4 100) # Correspond aux seuils + vitesse max # Check if the iDRAC host is set to 'local' or not then set the IDRAC_LOGIN_STRING accordingly if [[ $IDRAC_HOST == "local" ]] then # Check that the Docker host IPMI device (the iDRAC) has been exposed to the Docker container if [ ! -e "/dev/ipmi0" ] && [ ! -e "/dev/ipmi/0" ] && [ ! -e "/dev/ipmidev/0" ]; then echo "/!\ Could not open device at /dev/ipmi0 or /dev/ipmi/0 or /dev/ipmidev/0, check that you added the device to your Docker container or stop using local mode. Exiting." >&2 exit 1 fi IDRAC_LOGIN_STRING='open' else echo "iDRAC/IPMI username: $IDRAC_USERNAME" echo "iDRAC/IPMI password: $IDRAC_PASSWORD" IDRAC_LOGIN_STRING="lanplus -H $IDRAC_HOST -U $IDRAC_USERNAME -P $IDRAC_PASSWORD" fi get_Dell_server_model if [[ ! $SERVER_MANUFACTURER == "DELL" ]] then echo "/!\ Your server isn't a Dell product. Exiting." >&2 exit 1 fi # Log main informations echo "Server model: $SERVER_MANUFACTURER $SERVER_MODEL" echo "iDRAC/IPMI host: $IDRAC_HOST" # Log the check interval echo "Check interval: ${CHECK_INTERVAL}s" echo "" # Define the interval for printing readonly TABLE_HEADER_PRINT_INTERVAL=10 i=$TABLE_HEADER_PRINT_INTERVAL # Set the flag used to check if the active fan control profile has changed IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true # Check present sensors IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=true IS_CPU2_TEMPERATURE_SENSOR_PRESENT=true retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT if [ -z "$EXHAUST_TEMPERATURE" ] then echo "No exhaust temperature sensor detected." IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT=false fi if [ -z "$CPU2_TEMPERATURE" ] then echo "No CPU2 temperature sensor detected." IS_CPU2_TEMPERATURE_SENSOR_PRESENT=false fi # Output new line to beautify output if one of the previous conditions have echoed if ! $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT || ! $IS_CPU2_TEMPERATURE_SENSOR_PRESENT then echo "" fi # Fonction pour régler la vitesse des ventilateurs #set_fan_speed() { # local speed=$1 # # Commande pour définir la vitesse des ventilateurs via l'iDRAC # # Par exemple: ipmitool raw command # ipmitool -I lanplus -H ${IDRAC_HOST} -U ${IDRAC_USERNAME} -P ${IDRAC_PASSWORD} raw 0x30 0x30 0x02 0xff ${speed} #} # Start monitoring while true; do # Sleep for the specified interval before taking another reading sleep $CHECK_INTERVAL & SLEEP_PROCESS_PID=$! retrieve_temperatures $IS_EXHAUST_TEMPERATURE_SENSOR_PRESENT $IS_CPU2_TEMPERATURE_SENSOR_PRESENT # Define functions to check if CPU 1 and CPU 2 temperatures are above the threshold function CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; } if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT then function CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_THRESHOLD ]; } fi # Initialize a variable to store the comments displayed when the fan control profile changed COMMENT=" -" # Check if CPU 1 is overheating then apply Dell default dynamic fan control profile if true if CPU1_OVERHEAT then apply_Dell_fan_control_profile if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED then IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true # If CPU 2 temperature sensor is present, check if it is overheating too. # Do not apply Dell default dynamic fan control profile as it has already been applied before if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT then COMMENT="CPU 1 and CPU 2 temperatures are too high, Dell default dynamic fan control profile applied for safety" else COMMENT="CPU 1 temperature is too high, Dell default dynamic fan control profile applied for safety" fi fi # If CPU 2 temperature sensor is present, check if it is overheating then apply Dell default dynamic fan control profile if true elif $IS_CPU2_TEMPERATURE_SENSOR_PRESENT && CPU2_OVERHEAT then apply_Dell_fan_control_profile if ! $IS_DELL_FAN_CONTROL_PROFILE_APPLIED then IS_DELL_FAN_CONTROL_PROFILE_APPLIED=true COMMENT="CPU 2 temperature is too high, Dell default dynamic fan control profile applied for safety" fi else # Adjust fan speed based on temperature thresholds for i in ${!TEMP_THRESHOLDS[@]}; do if [ $CPU1_TEMPERATURE -le ${TEMP_THRESHOLDS[$i]} ]; then set_fan_speed ${FAN_SPEEDS[$i]} break fi done # Si la température est supérieure à tous les seuils, définir la vitesse maximale if [ $CPU1_TEMPERATURE -gt ${TEMP_THRESHOLDS[-1]} ]; then set_fan_speed ${FAN_SPEEDS[-1]} fi # apply_user_fan_control_profile # Check if user fan control profile is applied then apply it if not if $IS_DELL_FAN_CONTROL_PROFILE_APPLIED then IS_DELL_FAN_CONTROL_PROFILE_APPLIED=false COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_THRESHOLD°C), user's fan control profile applied." fi fi # Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response # No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE then disable_third_party_PCIe_card_Dell_default_cooling_response THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled" else enable_third_party_PCIe_card_Dell_default_cooling_response THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled" fi # Print temperatures, active fan control profile and comment if any change happened during last time interval if [ $i -eq $TABLE_HEADER_PRINT_INTERVAL ] then echo " ------- Temperatures -------" echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Third-party PCIe card Dell default cooling response Comment" i=0 fi printf "%19s %3d°C %3d°C %3s°C %5s°C %40s %51s %s\n" "$(date +"%d-%m-%Y %T")" $INLET_TEMPERATURE $CPU1_TEMPERATURE "$CPU2_TEMPERATURE" "$EXHAUST_TEMPERATURE" "$CURRENT_FAN_CONTROL_PROFILE" "$THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS" "$COMMENT" ((i++)) wait $SLEEP done